Państwowy Instytut Weterynaryjny - Państwowy Instytut Badawczy

    • Zaloguj
    Zobacz pozycję 
    •   Strona główna Repozytorium
    • PIWet - PIB
    • Publikacje
    • Zobacz pozycję
    •   Strona główna Repozytorium
    • PIWet - PIB
    • Publikacje
    • Zobacz pozycję
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Liquid chromatography-tandem mass spectrometry methods for determination of stanozolol and 16β-hydroxy-stanozolol in animal urine.

    Journal of Veterinary Research

    Thumbnail
    Oglądaj/Open
    10.2478_jvetres-2023-0030.pdf (1.106MB)
    Data
    2023
    Autor
    Matraszek-Żuchowska, Iwona
    Kłopot, Alicja
    Sielska, Katarzyna
    Korycińska, Beata
    Witek, Sebastian
    Zdonek, Paulina
    Jedziniak, Piotr
    Metadane
    Pokaż pełny rekord
    Streszczenie
    Introduction: Because of the activities and effects they induce, hormones are prohibited for use for anabolic purposes in farm animals intended for slaughter, which is regulated in the European Union by relevant legal provisions. Therefore, there is an obligation to monitor residues of hormones in animals and food of animal origin to ensure consumer safety. A hormone banned but used formerly for fattening cattle, stanozolol, and its metabolite 16β-OH-stanozolol are synthetic compounds that belong to a large group of steroid hormones. This study investigates residues of these compounds in animal urine. Material and Methods: From 2006–2022, 2,995 livestock urine samples were tested for stanozolol residues in Poland as part of the National Residue Monitoring Programme. A liquid chromatography–tandem mass spectrometry method to determine stanozolol and 16β-OH-stanozolol in animal urine was developed and validated according to the required criteria. Urine sample analysis was based on enzymatic hydrolysis of hormones potentially present in it to the free form, extraction of them from the sample with a mixture of n-hexane and butyl alcohol, purification of an extract on an NH2 amine column and finally, instrumental detection. Results: The apparent recovery and precision parameters of the developed method were in line with the established criteria, while its decision limits CCα and detection capabilities CCβ were lower than the recommended concentration for analytical purposes set at 2 μg L−1 (valid until December 15, 2022; currently set as 0.5 μg L−1). Conclusion: All examined samples were compliant with the evaluation criteria.
    URI
    https://sciendo.com/article/10.2478/jvetres-2023-0030
    Zbiory
    • Publikacje [643]

    DSpace software copyright © 2002-2016  DuraSpace
    Kontakt z nami | Wyślij uwagi
    Theme by 
    Atmire NV
     

     

    Przeglądaj

    Całe RepozytoriumZbiory i kolekcjeDaty wydaniaAutorzyTytułyTematyTa kolekcjaDaty wydaniaAutorzyTytułyTematy

    Moje konto

    Zaloguj

    Statystyki

    Przejrzyj statystyki użycia

    DSpace software copyright © 2002-2016  DuraSpace
    Kontakt z nami | Wyślij uwagi
    Theme by 
    Atmire NV